Lines Matching full:pair
3 Diagnostic Concept for Investigating Twisted Pair Ethernet Variants at OSI Layer 1
14 Pair Ethernet at OSI Layer 1. If you're facing unstable links, speed drops,
29 environments, including **Single-Pair Ethernet (SPE)** and **Multi-Pair
139 For both **Single-Pair Ethernet (SPE)** and **Multi-Pair Ethernet (MPE)**
166 Port: Twisted Pair
200 Port: Twisted Pair
244 2. **PoDL (Single-Pair Ethernet)**:
336 The following are the typical outputs for **Single-Pair Ethernet (SPE)** and
337 **Multi-Pair Ethernet (MPE)**:
339 - **For Single-Pair Ethernet (SPE)**:
345 Pair A, fault length: 25.00m
346 Pair A code Open Circuit
353 - **For Multi-Pair Ethernet (MPE)**:
359 Pair A code OK
360 Pair B code OK
361 Pair C code Open Circuit
363 Here, Pair C is reported as having an open circuit, while Pairs A and B are
389 - Some PHYs may report a **Short within Pair** if the link partner is in
433 - **Short within Pair**:
435 - A **Short within Pair** indicates an unintended connection within the same
436 pair of wires, typically caused by physical damage to the cable.
441 - **Short to Another Pair**:
443 - A **Short to Another Pair** means the wires from different pairs are
780 can hunt down every elusive network issue - one twisted pair at a time.