Lines Matching full:be
41 description: boolean, regulator should never be disabled
49 This property is intended to only be used for regulators where
58 description: allow the regulator performance level to be configured
63 disabling ramp rate, it should be explicitly initialised to zero (regulator-ramp-delay
105 for the regulator at run-time. Elements may be specified in any order.
131 hardware performs emergency shutdown. Zero can be passed to disable
132 protection and value '1' indicates that protection should be enabled but
133 limit setting can be omitted.
138 Zero can be passed to disable error detection and value '1' indicates
139 that detection should be enabled but limit setting can be omitted.
143 is assumed still to be functional but approaching limit where it gets
144 damaged. Recovery actions should be initiated. Zero can be passed to
146 be enabled but limit setting can be omitted.
150 hardware performs emergency shutdown. Zero can be passed to disable
151 protection and value '1' indicates that protection should be enabled but
152 limit setting can be omitted. Limit is given as microvolt offset from
158 Zero can be passed to disable error detection and value '1' indicates
159 that detection should be enabled but limit setting can be omitted. Limit
164 is assumed still to be functional but approaching limit where it gets
165 damaged. Recovery actions should be initiated. Zero can be passed to
167 be enabled but limit setting can be omitted. Limit is given as microvolt
172 hardware performs emergency shutdown. Zero can be passed to disable
173 protection and value '1' indicates that protection should be enabled but
174 limit setting can be omitted. Limit is given as microvolt offset from
180 Zero can be passed to disable error detection and value '1' indicates
181 that detection should be enabled but limit setting can be omitted. Limit
186 hardware is assumed still to be functional but approaching limit where
187 it gets damaged. Recovery actions should be initiated. Zero can be passed
189 be enabled but limit setting can be omitted. Limit is given as microvolt
198 be carried out in preparation for potential power loss.
202 hardware performs emergency shutdown. Zero can be passed to disable
203 protection and value '1' indicates that protection should be enabled but
204 limit setting can be omitted.
209 Zero can be passed to disable error detection and value '1' indicates
210 that detection should be enabled but limit setting can be omitted.
214 hardware is assumed still to be functional but approaching limit where it
215 gets damaged. Recovery actions should be initiated. Zero can be passed to
217 be enabled but limit setting can be omitted.
230 is 2-way - all coupled regulators should be linked with each other.
231 A regulator should not be coupled with its supplier.
244 that can be changed safely in a single step.
259 description: regulator should be on in suspend state.
263 description: regulator should be off in suspend state.
267 description: minimum voltage may be set in suspend state.
270 description: maximum voltage may be set in suspend state.
273 description: the default voltage which regulator would be set in
280 in suspend can be changed in runtime.