Lines Matching +full:fast +full:- +full:mode
5 Contact: linux-[email protected]
14 Contact: linux-[email protected]
23 Contact: linux-[email protected]
32 Contact: linux-[email protected]
43 Contact: linux-[email protected]
66 Contact: linux-[email protected]
81 Contact: linux-[email protected]
94 read-only reporting, unless the 'online' state of the supply
106 Contact: linux-[email protected]
124 Contact: linux-[email protected]
128 Maximum TBAT temperature trip-wire value where the supply will
129 notify user-space of the event.
133 Maximum supply temperature trip-wire value where the supply
134 will notify user-space of the event.
137 user-space needs to know if the temperature has crossed an
148 Contact: linux-[email protected]
153 Minimum TBAT temperature trip-wire value where the supply will
154 notify user-space of the event.
158 Minimum supply temperature trip-wire value where the supply
159 will notify user-space of the event.
161 This is normally used for the charging scenario where user-space
173 Contact: linux-[email protected]
190 Contact: linux-[email protected]
207 Contact: linux-[email protected]
224 Contact: linux-[email protected]
241 Contact: linux-[email protected]
253 read-only reporting, unless the 'online' state of the supply
265 Contact: linux-[email protected]
271 Valid values: 0 - 100 (percent)
275 Contact: linux-[email protected]
277 Maximum battery capacity trip-wire value where the supply will
278 notify user-space of the event. This is normally used for the
279 battery discharging scenario where user-space needs to know the
286 Valid values: 0 - 100 (percent)
290 Contact: linux-[email protected]
292 Minimum battery capacity trip-wire value where the supply will
293 notify user-space of the event. This is normally used for the
294 battery discharging scenario where user-space needs to know the
301 Valid values: 0 - 100 (percent)
305 Contact: linux-[email protected]
310 Values close to 0% will be returned after (re-)calibration
317 Valid values: 0 - 100 (percent)
321 Contact: linux-[email protected]
333 Contact: linux-[email protected]
344 Contact: linux-[email protected]
354 Contact: linux-[email protected]
360 Valid values: 0 - 100 (percent)
364 Contact: linux-[email protected]
374 Valid values: 0 - 100 (percent)
378 Contact: linux-[email protected]
384 Fast:
385 Quickly charge the battery using fast-charge
391 battery life with this mode. Vendor tooling may
414 "Unknown", "N/A", "Trickle", "Fast", "Standard",
419 Contact: linux-[email protected]
422 charge-types with the currently active type surrounded by square
423 brackets, e.g.: "Fast [Standard] Long_Life".
430 Note charge-types which contain a space such as "Long Life" will
432 When writing charge-types both variants are accepted.
436 Contact: linux-[email protected]
447 Contact: linux-[email protected]
463 Contact: linux-[email protected]
465 Reports the charging current applied during pre-charging phase
474 Contact: linux-[email protected]
490 Contact: linux-[email protected]
493 is read-only reporting although for some supplies this can be
504 Contact: linux-[email protected]
513 inhibit-charge: Do not charge while AC is attached
514 force-discharge: Force discharge while AC is attached
519 Contact: linux-[email protected]
526 "Unknown", "NiMH", "Li-ion", "Li-poly", "LiFe",
532 Contact: linux-[email protected]
544 Contact: linux-[email protected]
559 Contact: linux-[email protected]
574 Contact: linux-[email protected]
578 system-level knowledge or user input (e.g. This is part of the
592 Contact: linux-[email protected]
596 system-level knowledge or user input. Use preferably this
606 Contact: linux-[email protected]
610 between online states (e.g. Fixed -> Programmable for a PD_PPS
619 1: Online Fixed - Fixed Voltage Supply
620 2: Online Programmable - Programmable Voltage Supply
625 Contact: linux-[email protected]
628 the supply, for example it can show if USB-PD capable source
631 Access: For power-supplies which consume USB power such
633 the connected USB power source and is Read-Only.
635 For power-supplies which act as a USB power-source such as
644 What: /sys/class/power/ds2760-battery.*/charge_now
656 What: /sys/class/power/ds2760-battery.*/charge_full
665 What: /sys/class/power_supply/max14577-charger/device/fast_charge_timer
671 charger operates in fast-charge mode. When the timer expires
672 the device will terminate fast-charge mode (charging current
677 - 5, 6 or 7 (hours),
678 - 0: disabled.
680 What: /sys/class/power_supply/max77693-charger/device/fast_charge_timer
686 charger operates in fast-charge mode. When the timer expires
687 the device will terminate fast-charge mode (charging current
692 - 4 - 16 (hours), step by 2 (rounded down)
693 - 0: disabled.
695 What: /sys/class/power_supply/max77693-charger/device/top_off_threshold_current
701 entering top-off charging mode. When charging current in fast
702 charge mode drops below this value, the charger will trigger
703 interrupt and start top-off charging mode.
707 - 100000 - 200000 (microamps), step by 25000 (rounded down)
708 - 200000 - 350000 (microamps), step by 50000 (rounded down)
709 - 0: disabled.
711 What: /sys/class/power_supply/max77693-charger/device/top_off_timer
717 charger operates in top-off charge mode. When the timer expires
718 the device will terminate top-off charge mode (charging current
723 - 0 - 70 (minutes), step by 10 (rounded down)
725 What: /sys/class/power_supply/bq24257-charger/ovp_voltage
730 This entry configures the overvoltage protection feature of bq24257-
737 - 6000000, 6500000, 7000000, 8000000, 9000000, 9500000, 10000000,
740 What: /sys/class/power_supply/bq24257-charger/in_dpm_voltage
746 bq24257-type charger devices. Once the supply drops to the configured
748 drop of the supply. When the IC enters this mode, the charge current is
753 - 4200000, 4280000, 4360000, 4440000, 4520000, 4600000, 4680000,
756 What: /sys/class/power_supply/bq24257-charger/high_impedance_enable
761 This entry allows enabling the high-impedance mode of bq24257-type
763 standby mode with the switch mode controller disabled. When disabled,
768 - 1: enabled
769 - 0: disabled
771 What: /sys/class/power_supply/bq24257-charger/sysoff_enable
776 This entry allows enabling the sysoff mode of bq24257-type charger
784 - 1: enabled
785 - 0: disabled
789 Contact: linux-[email protected]
800 Contact: linux-[email protected]
806 Valid values: 1-12
810 Contact: linux-[email protected]
815 Valid values: 1-31
819 Contact: linux-[email protected]